Direct measurement of the moving stage’s absolute position eliminates reliance on drivetrain kinematics, enabling ultra-precision fully closed-loop control.
Semi-closed-loop control derives position from motor shaft rotation, leaving mechanical deformation outside the feedback loop.
Direct metrology measures stage displacement relative to a fixed reference, bringing mechanical errors into the control loop for active compensation.
Mechanical errors accumulate between the commanded and actual stage positions, remaining undetected by the controller.
The scale and readhead are mounted directly to the stage base and moving table, feeding actual displacement (Xactual) back to the controller.
Active Drivetrain Error Compensation
The controller monitors the moving stage’s absolute position in real time rather than inferring it from motor feedback. Kinematic errors, elastic deformation, and thermal displacement are captured within the feedback loop for active position correction.
Scale material and fabrication method are critical to encoder accuracy along a gonio stage’s curved travel path.
Our precision-machined arc geometry eliminates distortion caused by forced bending.
Flexible steel tape is bent to fit the mounting surface, introducing mechanical constraints and potential instability from forced curvature.
The glass scale is precision-machined to match the gonio stage’s curvature, eliminating bending-induced stress and associated errors.
* Physics-based prediction (Radius R=50 mm, Scale thickness t=0.2 mm)
| Measurement Architecture |
Absolute Position Feedback Fully Closed-Loop Direct Metrology |
|---|---|
| Scale Material & Geometry |
Low-CTE Glass & Distortion-Free Arc-Shaped (for Gonio Stages) |
| System Resolution | Up to 28-bit resolution (~25 nm | ~0.00002°) |
| Form Factor | Ultra-compact readhead for stacked multi-axis assemblies |
| Kinematic Error Compensation |
Real-time backlash and lead error compensation (FOC, Fully Closed-Loop) |
Optimize ball screw drive performance for your radius, travel range, target resolution, and control system.